1. PRODUCTS&COMPANY IDENTIFICATION

PRODUCT NAME:VALVE REGULATED SEALED LEAD ACID RECHARGEABLE BATTERY 
MANUFACTURER'S NAME:Baiyida Tech. Co., Ltd 
MANUFACTURER'S ADDRESS:Room811C,Huiyi Fortune Center,Bulong Road,Dalang Street,Longhua New District,Shenzhen 

TELEPHONE NUMBER: 0755-23774105 
FACSIMILE NUMBER: 0755-23774105

 
COMPONENTS %WEIGHT TLV LD 5O ORAL LC50 DEIALATION LC50 CONTACT
Lead(Pb,PbO2,PbSO4) About 70% N/A (500)mg/kg N/A N/A
Sulfuret acid About 10% 1mg/m3 (2.140)mg/kg N/A N/A
Fiber glass separators About 5% N/A N/A N/A N/A
ABS About 5% N/A N/A N/A N/A
 

3.PHYSICAL DATA

COMPONENTS DENSITY MELTING POINT SOLLUBILITY(H2O) ODOR APPEARANCE
Lead 11.34 327.4โ„ƒ(Boiling) None None Sliver-Gray Metal
Lead Sulfuric 6.2 1070โ„ƒ(Boiling) 40mg/l(15โ„ƒ) None White Powder
Lead dioxide 9.4 290โ„ƒ(Boiling) None None Brown Powder
Sulfuric Acid About1.3 About114โ„ƒ(Boiling) 100% ACIDE Clear liquor
Fiber glass separators N/A N/A SLIGHT TDXIC WHITE FIBROUS GLASS
ABS N/A N/A NONE NO ODOR SOLIO
 

4.FIRST AID MEASURES

After skin contact:innediatel remove contaminated clothing,wash skin thoroughly with mild soap/water.
Flush w/lukewarm water for 15 minutes.
If stickly,usd waterless cleaner first. 
Seek medical attention if ill effect or irritation develops. 
After eye contact:In case of eye contact,immediately rinse with clean water for 20-30minutes.Retract eyelids often.Obtain emergency medical attention.Other 
information:during emergency condition,overexposure to decomposition products may cause a bealth hazard.
 

5.FIRE-FIGHTING MEASURES

Suitablee extinguishing media:water,foam,carbon dioxide or dry chemical Special risks: no Special protective equipment for fire fighting:full protective equipment,including self contained breathing apparatus is needed to protect fire fighters from exposure.Other information:during emergency condition, overexposure to decomposition products may cause a bealth hazard.
 

6.ACCIDENTAL RELEASE MEASURES

Person-related protection measures: absorption on inert material and disposed of in accordance with Federal.State and local regulation. Procedureds for cleaning/absorption:absorb on sand or vermiculite and place in closed containers for disposal.Ventilate area and wash spill site after matcrial pickup is complete.
 

7.HANDLING AND STORACE

Handling :No needed wear safety equipment.Don't get in eyes,skin and clothing.Avoid exposure.Wash thoroughly after handling. Storage:store drums away from heat soures,strong oxidizers,radiation ,sunshine and other initiators.Use product within six months of reccipt for optinum results.Keep contalners tightly closed.Keep away from heat and sunshine.Store in a cool place.
 

8.FLAMMABILLITY DATA

COMPONENTS FLASHPIONT EXPLOSIVE LIMITS COMMENTS
Lead None None ใ€€
Sulfuric Acid None None ใ€€
Hydrogen ใ€€ 4%-74.2% Sealed batteries can emit Hydrogen only a over charged(float voltage ๏ผž2.4vpc)
Fiber glass separators N/A N/A please wear self contained breathing apparatus in case of fire
ABS N/A N/A Temperature over 300โ„ƒ may retease comburstible,please wear positive pressure self contained breathing apparatus

 

9.STABLITY AND REACTIVITY

Conditions to be avoided:Sunshine,High temperatures,localized heat sources(ie,drum or band beaters),oxidizing conditions,freezing condition,direct sunlight,ultraviolet radiation. Inert gas blanketing. Substance to be avoided:Strong oxidizers,strong reducers,free radical initiators,inert gases,oxygen scavengers. Hazardous decomposition products:Acrid smoke-fumes/curbon monoxide/carbon dioxide and perhaps other toxic vapors maybe released during a fire involving this product. Further information:

 

10.REACTICITY DATA

COMPONENT SulfuricAcid
STABILITY Stable at all temper atures
POLYMERIZATION Will not polymatize
INCOMPATIBILITY Reactive metals,strong bases,most organic compounds
DECOMPOSITION PRODUCTS Sulfuric dioxide,trioxide,hydrogen sulfide,hydrogen
CONDITIONS TO AVOID Prohibit smoking,sparks,etc.from battery charging from battery charging area.Avoid mixing acid with other chemicals.
 

11.SPILL OR LEAK PROCEDURES

ACTION TAKEN FOR THE LEADAGE OR SPILLS
If sulfuric acid is spilled from a battery,neutralize the acid with sudium biearbonate(baking soda),sodium carbon(soda ash),or calclum oxide(lime). Flush the area with water discard to the sewage systems.Do not allow acid into the sewage systems before it is neutralized. WASTE DISPOSAL METHOD:Neutralized Acid may be flushed down the sewer,Usded batteries must be treated as hazardous waste and disposed of according to local policy and National Laws.A copy of this material satety data must be supplied to any scrap dealer.

 
12.ELECTRICAL SAFETY

Due to the battery's low internal resisitance and high power density.High leves of short circuit can be developed across the battery terminals. Do not put tools or cables on the battery.Use insulated tools only.Strictly follow all the instruction for installation and diagrams when installing or maintaining battery systems.

 
13.HEALTH HAZARD DATA

LEAD:The toxic effects of lead are accumulative and slow to appear.If affects the kidneys,reproductiye,and central nervous system. The symptoms of lead overexposure are anemla,vomlting,headache,stomach pain(lead colic),dizziness,loss of appetite,and muscle and joint pain.Exposure to lead frum a battery most often occurs during lead reclaim operations through the breathing or in gestion of lead dust and fumes. SULFURIC ACID:Sulfuric acid is a strong corrosive.Contact with acid can cause severe burns on the skin and in the eyes. In question of sulfuric acid will cause GI tract burns.Acid can be release if the battery case is damaged or if the vents are tampered with. FIBERGLASS SEPARATOR:Fibrous glass is an irritant of the upper respiratory tract,skin and eyes,Please use the relative protection gears if necessary.

 
14.TRANSPORTATION INFORMATION
Acceptable modes of transportation:air,rall,Roadand water. Batteries must be protected so as to prevent short circuit and must be securely packead and marked on the container"Non-Spillable"

15.REGULATORY INFORMATION

16.OTHER INFORMATION
 